Skip to main content

v1.3

Major VersionM

by Alina

Introduction

In the rare case that your Palette 2 does not power on or something has gone wrong during the use of the Firmware Updater, please follow the steps below. Please ensure that your Palette is plugged into both the power and USB cables when following the instructions unless otherwise noted.

You can find the updater here.

Note: These instructions were updated on May 10, 2019 for the new firmware updater (v1.1.2). Please ensure you are using this version of the firmware updater in order to proceed with installing firmware later than v7.0.6.

    • If you've tried to update Palette's firmware and received an error code, first power off and power on your Palette, restart the Firmware Updater and try the update again by selecting "Install Latest". If the progress bar does not advance after approximately one minute, please try to restart one more time before proceeding with the steps below.

  1. Open the Firmware Updater. After selecting Next on the first screen, check the Advanced Options field.
    • Open the Firmware Updater. After selecting Next on the first screen, check the Advanced Options field.

  2. Before proceeding, ensure that you have removed any USB connections from your computer that will communicate serially (3D printers, devices, etc.). Once this is done, go to the Port dropdown and select "COM..." for Windows and "/Dev/..." for Mac. Please ensure that 'Software bootloader' is checked.
    • Before proceeding, ensure that you have removed any USB connections from your computer that will communicate serially (3D printers, devices, etc.). Once this is done, go to the Port dropdown and select "COM..." for Windows and "/Dev/..." for Mac. Please ensure that 'Software bootloader' is checked.

    • From here, select Install Latest. You should see the progress bar start on the updater. If you're still running into errors or the bar does not load in approximately 1 minute, please proceed to the next step.

    • Please download this Zip file (Firmware version 9.2.9)

    • Go to Advanced Options page and ensure that the port is selected properly (not Auto) and that 'Software bootloader' is checked. Select Main and upload file 'P2EE01.bin from the unzip file.

    • Return to Advanced Options. Ensure the proper port is selected and that 'Software bootloader' is checked. Click Screen and upload the file 'P2EE02.bin' from the zip file.

    • Once this is uploaded, return to Advanced Options and select the proper port and that 'Software bootloader' is checked. Once done, select Graphics and upload the file 'ui.min' from the zip file.

    • If you're unable to detect Palette when running the firmware updater, please try the following:

    • For Windows users, depending on the version of your OS, a driver may be missing. Please download the driver found here, reboot your computer, and try to detect the Palette again.

    • For Mac users, we've seen instances where a conflicting FTDI extension causes communication issues. Deleting this extension will allow the firmware to install correctly.

    • Other slicers and Arduino sometimes will block the firmware updater from accessing Palette's communication port. To ensure that this doesn't happen, please close other programs that have serial communications.

    • The connection to the I/O board may be loose. Please follow the steps here to access the I/O board to check the connections.

    • If you are still experiencing issues such as Palette's screen not powering on, or a "handshake" error, please follow the steps here if you have an S unit and here if you have a non-S unit.

Conclusion

If you have any questions, please contact us at support@mosaicmfg.com.

One other person completed this guide.

Mosaic Support

Member since: 04/02/2020

155 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 2

Past 7 Days: 6

Past 30 Days: 33

All Time: 4,017

Contact Mosaic Support Team

© 2024 Mosaic Manufacturing Ltd.