Skip to main content

v1.1

Minor Versionm

by Frank

  1. Remove the top and bottom lids of Palette+. Remove the screen so that you have access to the merger. Turn Palette+ upside down to access the screws for the splicing unit. Loosen, but do not fully remove these 3 screws. Next, loosen, but do not remove, the 4 screws on the side of Palette+'s frame.
    • Remove the top and bottom lids of Palette+. Remove the screen so that you have access to the merger.

    • Turn Palette+ upside down to access the screws for the splicing unit. Loosen, but do not fully remove these 3 screws.

    • Next, loosen, but do not remove, the 4 screws on the side of Palette+'s frame.

  2. Once these screws are loosened, tighten the screw next to the opto sensor. This will tighten the merger and help with the alignment.
    • Once these screws are loosened, tighten the screw next to the opto sensor. This will tighten the merger and help with the alignment.

    • You may need to remove the hot tool in order to get enough room to tighten this screw. If this is the case, please follow the instructions in this support article to re-align the hot tool. It may also help to remove the back lid of Palette+.

    • Once the opto-sensor screw is tightened, try to manually feed filament through the merger and see if there is any resistance. Once you've found that all four drives can pass filament through, re-tighten the screws from steps 2 and 3 (please avoid over tightening these screws).

Conclusion

If you have any additional questions, please send us a message at support@mosaicmfg.com